Curtain- Wall

Curtain Wall is another type of glassy façade that uses aluminum profiles instead of iron frame and the view is like mesh and a combination of aluminum and glass. Curtain Wall itself is considered a structure.
This type of facade engineering, need no Self Support iron foundations and has unlimited color variation that use of the wood plans for it is possible also.
This system in facing vertical and lateral stresses such as wind, earthquakes and severe strokes is quite stable. Extraordinarily & unique beauty of this structure in the view is its final score. Thickness of Glass used in the system is 18 to 40 mm and performs the acoustic & thermal isolation of building completely. Beautiful and static design of this system with no use of screws and rivets in the assembly and design of hidden Opener in the system In addition to beauty and excellent visibility causes the rising of resistance coefficient, sealing & airtight.
Curtain wall could be classified to two main categories including: Face cap & Full Frameless.

 


 

Using Special caps in Face cape and lack of cap in Full Frameless is the most obvious aspect in the differentiation of these two systems.
In the design of Profiles in the system design issues related to the earthquake, wind and static compliance calculations are observance and materials needed for each project according to the demands of each project is calculated and characteristics of relevant Curtain wall profiles are determined. Below examples of calculation tables are presented.

Using Special caps in Face cape and lack of cap in Full Frameless is the most obvious aspect in the differentiation of these two systems.
In the design of Profiles in the system design issues related to the earthquake, wind and static compliance calculations are observance and materials needed for each project according to the demands of each project is calculated and characteristics of relevant Curtain wall profiles are determined. Below examples of caFor example in the table above for the structural modulation in height of 15 m and be such that every 4 meters can be mounted picket preservatives, 80 cm of transverse distance and less for sections size 12 is recommended.  
Specifications

  • Possibility of using double or 3 layer
  • Possibility of creating temperature insulation surface by using thermal break profiles  Creation of insulation surface temperature profiles using a Thermal Break
  • Possibility of using different cap
  • Possible to run all aluminum
  • Unrestricted color
  • Possibility of using different sections and sizes in the need of project

lculation tables are presented.

 

Implementation Methods
  • Modulation provided according to primary plan and calculation of the effective coefficient in the structural stability and also considering the amount of material waste
  • Construction & assembly of curtain-walls modules
  • Start of executive operations: implementation and execution of the main belts
  • Run of retainer bracket
  • Stabilization and Reclage of Curtain walls by screws & bolts
  • Glass Installation